RS85

MV-Flow™

MV-Flow™ offers a novel alternative to Color Doppler for visualizing slow flow microvascularized structures.

S-Shearwave Imaging™

S-Shearwave Imaging™ allows for non-invasive assessment of the stiffness of tissue/lesions in the breast and liver, by providing an advanced level of diagnostic information.


RS85 is Samsung's premium ultrasound system that adopted the integrated solution. Built with exquisite image quality and expert tools, it empowers professionals to make faster and more confident decisions.

Improved Diagnostic Confidence

Samsung's image enhancing and artifact suppressing technologies and S-Vue™ transducers together provide clear, detailed imaging that you can count on to help improve diagnostic confidence and imaging continuity.

S-Vue™ Transducers

S-Vue™ transducers provide more efficient piezoelectric properties, resulting in wider bandwidths that enable better penetration and higher quality resolution on even challenging patients.

S-Vision™ imaging engine

With the S-Vision™ imaging engine built into RS85, the digital signals produce clear, detailed resolution and tissue uniformity for various types of applications in general imaging.



S-Harmonic™

This new harmonic technology improves image clarity, near to far. Reducing signal noise, S-Harmonic™ provides more uniform ultrasound images. Combined with the S-Vue™ transducers, S-Harmonic™ takes RS85 image quality one step further.

HQ Vision™

HQ Vision™ is a new, advanced technology for visualizing anatomical structures. With improved image clarity, this feature helps make a reliable diagnosis quickly.

ClearVision

The noise reduction filter improves edge enhancement and creates sharper 2D images for optimal diagnostic performance. The integration of specialized Samsung technology results in a notable improvement in image quality. In addition, ClearVison provides application-specifice optimization and advanced temporal resolution in live scan mode.

More Valuable Information

Expert tools offer new perspectives and provide additional information for confident decision making.


MV-Flow™

MV-Flow™ offers a novel alternative to Color Doppler for visualizing slow flow microvascularized structures. High frame rates and advanced filtering enable MV-Flow™ to provide a detailed view of blood flow in relation to surrounding tissue or pathology with enhanced spatial resolution and temporal resolution.

CEUS+

CEUS+ technology uses the unique properties of ultrasound contrast agents. When stimulated with low acoustic pressure, the oscillating microbubbles reflect both fundamental and harmonic frequency signals. In addition, Samsung's technologies provide a clear visualization of vessels and blood flow for a more informed and confident diagnosis.

S-Fusion™

S-Fusion™ enables simultaneous localization of a lesion using real-time ultrasound in conjunction with other volumetric imaging modalities. Samsung's Auto Registration helps quickly and precisely fuse the images, increasing efficiency and reducing procedure time. S-Fusion™ enables precise targeting during interventional and other advanced clinical procedures.

S-Fusion™ for Prostate

S-Fusion™ for Prostate allows precise targeting during prostate biopsies. Based on 3D models created with MR data sets, S-Fusion™ for Prostate provides biopsy guidance to help safely navigate and target the prostate.

Increased Consistency

With its advanced intelligent solutions, including an extensive range of quantification functions, RS85 provides measurement consistency while reducing variability between users.

S-Shearwave Imaging™

S-Shearwave Imaging™ allows for non-invasive assessment of the stiffness of tissue/lesions in the breast and liver, by providing an advanced level of diagnostic information. The color-coded elastogram, quantitative measurements (in kPa or m/s), dual or single display option, and user-selectable ROI (position and size) functions are especially useful for the accurate diagnosis of breast and liver diseases.



Arterial Analysis™

Arterial Analysis™ detects functional changes of vessels, providing measurement values such as the stiffness, intima-media thickness and pulse wave velocity of the common carotid artery. Since the functional changes occur before morphological changes, this technology supports the early detection of cardiovascular disease.

S-3D Arterial Analysis™

S-3D Arterial Analysis™ simplifies volume measurement of arterial plaque, providing 3D vessel modeling. With Samsung's S-3D Arterial Analysis™, obtaining information on the arterial plaque volume is surprisingly fast and easy even on difficult patients. In addition, it allows you to track the morphological changes of the artery.

S-Detect™ for Thyroid

S-Detect™ for Thyroid uses the advanced technology based on K-TIRADS, RUSS and ATA guideline* in detecting and classifying suspicious thyroid lesions semi-automatically. This state-of-the art technology helps you diagnose your patients with confidence and ease, providing accurate, consistent results and an automatic reporting feature.

S-Detect™ for Breast

S-Detect™ for Breast helps standardize reporting and classification of suspicious breast lesions by incorporating BIRADS® ATLAS* (Breast Imaging-Reporting and Data System, Atlas) into the tool. When the user selects a region of interest, S-Detect™ for Breast automatically defines the lesion boundaries, provides lexicon classification options, and images export for an enhanced and streamlined workflow.

Enhanced Efficiency

The RS85 has been designed to streamline your workflow by enhancing efficiency through reducing keystrokes and by combining multiple actions into one.

Transducers



Curved array transducers

CA1-7A

Abdomen, Obstetrics, Gynecology, Contrast

CA3-10A

Abdomen, Obstetrics, Gynecology, Pediatric, Vascular

CA2-8A

Abdomen, Obstetrics, Gynecology

CF4-9

Pediatric, Vascular

Linear array transducers

LM4-15B

Small parts, Vascular, Musculoskeletal

LA4-18B

Small parts, Vascular, Musculoskeletal

L3-12A

Small parts, Vascular, Musculoskeletal

LA3-16A

Small parts, Vascular, Musculoskeletal

LA2-9A

Small parts, Vascular, Musculoskeletal, Abdomen

LA3-16AI

Musculoskeletal

Volume transducers

V5-9

Obstetrics, Gynecology, Urology

LV3-14A

Musculoskeletal, Small parts, Vascular

Endocavity transducers

E3-12A

Obstetrics, Gynecology, Urology

Phased Array transducers

PM1-6A

Cardiac, TCD, Abdomen

PA3-8B

Cardiac, Pediatric, Abdomen

PA4-12B

Cardiac, Pediatric

CW transducers

CW6.0

Cardiac

DP2B

Cardiac

DP8B

Cardiac, Vascular

TEE transducer

MMPT3-7

Cardiac