RS80A with Prestige

Volume rendering technology for accurate measurement

S-3D Arterial Analysis measures artery plaque volume and tracks morphological changes. It helps accurate, early detection of cardiovascular diseases.

Evolving detection tool for lesion analysis

S-Detect™ for breast provides the characteristics of displayed lesion and a recommendation on whether the lesion is benign or malignant by adopting deep learning detection algorithm.



Superior image quality
S-Vision Architecture


S-Vision Beamformer

The S-Vision Beamformer receives returning signals through a sophisticated digital filtering system resulting in reduced side lobes, less noise and artifact.

S-Vision imaging engine

The S-Vision Beamformer receives returning signals through a sophisticated digital filtering system resulting in reduced side lobes, less noise and artifact.

Imaging becomes Even Better with S-Vue transducer
(Single Crystal Technology)

The S-Vue transducers provide broader bandwidth and higher sensitivity over conventional Samsung transducers. They enable higher resolution at depth thereby providing improved image quality even with technically challenging patients.

In addition, the ergonomically designed S-Vue transducer fits well in the hand and is easy to handle.



S-Harmonic

This new harmonic technology provides greater image uniformity from near to far field while reducing signal noise.

HQ Vision

HQ Vision represents new, advanced technology for visualizing anatomical structures. It helps to make a reliable diagnosis quickly.

For advanced lesion diagnosis
CEUS+

CEUS+ technology uses the unique properties of ultrasound contrast agents. When stimulated with low MI frequencies, the oscillating microbubbles reflect both basic frequencies and harmonic signals.

In addition, Samsung's latest technologies, VesselMax and FlowMax, provide a clear visualization of vessels and blood flow so that you can form an informed, reliable diagnosis with confidence.



S-Shearwave

S-Shearwave detects the velocity of the shearwave propagated through the targeted lesion and displays the numerical measurement of stiffness In kPa or m/s together with a Reliable measurement Index (RMI)*. S-Shearwave has the potential to reduce the number of conventional liver biopsies by providing quantitative tissue characteristic information.




E-Strain

E-Strain enables quick and easy calculation of the strain ratio between two regions of interest in day-to-day procedures such as breast, prostate or gynecological examinations.

E-Breast™

Unlike conventional ultrasound elastography, E-Breast™requires to select only one ROI to calculate the strain ratio.

E-Thyroid™

E-Thyroid™ uses pulsations from the adjacent Carotid Artery and provides an assessment of thyroid lesions.

S-Detect™ for Breast

S-Detect™ employs BI-RADS® scores for standardized analysis and classification of suspicious lesions. It provides the characteristics of displayed lesion and a recommendation on whether the lesion is benign or malignant. With 3 modes included in S-Detect™, users can set the level of sensitivity and specificity for a specific purpose.

S-Detect™ for Thyroid

S-Detect™ for Thyroid detects and classifies suspicious thyroid lesions semi-automatically based on Thyroid Image Reporting and Data System (TI-RADS) scores. This technology helps you diagnose your patients with confidence and ease, providing accurate, consistent results and an automatic reporting feature.

For advanced intervention procedure


S-Fusion

S-Fusion enables simultaneous localization of a lesion with a real-time ultrasound in conjunction with other 3D volumetric imaging modalities. Unlike the conventional image fusion technology, Samsung offers a quicker and more precise registration process. S-Fusion enables precise targeting during operations such as Percutaneous Needle Biopsy and Radiofrequency Ablation.

S-Tracking

S-Tracking increases the rate of accuracy during interventional procedures by providing the simulated path of the needle and the target mark in the live ultrasound image.

For cardiovascular disease


S-3D Arterial Analysis™

Based on the available 3D data, S-3D Arterial Analysis™ helps measure artery plaque volume for quantitative analysis purposes, as well as track morphological changes. This technology enables the accurate detection of cardiovascular diseases.




Arterial Analysis™

Arterial Analysis™ detects functional changes of vessels, providing measurement values such as the stiffness and intima-media thickness. Since the functional changes occur before morphological changes, this technology supports the early detection of cardiovascular diseases.

Strain+

Strain quantitativelydisplays a Bull's Eye which shows left ventricular motion and dyssynchrony at a glance.

Stress Echo

The Stress Echo package includes wall motion scoring and reporting. It includes exercise Stress Echo, pharmacologic Stress Echo, diastolic Stress Echo and free programmable Stress Echo.

Design for your convenience


Folding monitor

The folding monitor enables safe and secure transport.

13.3-inch tilting touch screen

The tilting touch screen adjusts to accommodate user viewing preference in any scanning environment.

6 way adjustable control panel

The RS80A with Prestige's 6 way adjustable control panel optimizes work environment to reduce repetitive stress. When off-mode, the control panel returns to home position for easier mobility.

23-inch LED display

The RS80A with Prestige features a 23-inch high definition LED display delivering excellent contrast resolution, image clarity and vibrant color in any lighting condition.

Simplified console design

The simplified control panel including 3D Navigator and intuitive grouping of console buttons streamlines system interaction for efficient patient scanning.

Swivel lock

A single pedal controls a swivel lock mechanism to conveniently secure console in place and accommodates efficient movement during a variety of scanning procedures.

Transducers



Curved array transducers

CA1-7A

Abdomen, Obstetrics, Gynecology, Contrast

CA2-8A

Abdomen, Obstetrics, Gynecology

CF4-9

Pediatric, Vascular

CA3-10A

Abdomen, Obstetrics, Gynecology, Pediatric, Vascular

Linear array transducers

LM4-15B

Small parts, Vascular, Musculoskeletal

LA4-18B

Small parts, Vascular, Musculoskeletal

L3-12A

Small parts, Vascular, Musculoskeletal

LA3-16A

Small parts, Vascular, Musculoskeletal

LA2-9A

Small parts, Vascular, Musculoskeletal, Abdomen

L7-16

Small parts, Vascular, Musculoskeletal

LA3-16AI

Musculoskeletal

Volume transducers

CV1-8A

Abdomen, Obstetrics, Gynecology

V5-9

Obstetrics, Gynecology, Urology

V4-8

Abdomen, Obstetrics, Gynecology

LV3-14A

Musculoskeletal, Small parts, Vascular

Endocavity transducers

E3-12A

Obstetrics, Gynecology, Urology

Phased array transducers

PM1-6A

Cardiac, TCD, Abdomen

PA3-8B

Cardiac, Pediatric, Abdomen

PA4-12B

Cardiac, Pediatric

CW transducers

CW6.0

Cardiac

DP2B

Cardiac

TEE transducer

MMPT3-7

Cardiac